| Fig. 7.22. Proper positioning of the thermostat on diesel engines of 2.5 liters
|
Set the thermostat so that the bleed screw located on top (Fig. 7.22). Install O-ring into the housing of the thermostat.
| Fig. 7.21. Sliding the toothed belt tensioner pulley and bolt arrangement (1-3) securing thermostat housing
|
Install the thermostat housing and fix bolts, having tightened their moment of 10 Nm. In the thread of the bolt 2 (see. Fig. 7.21), apply sealant, thread lock. Slide the timing belt on the tensioner pulley.
| Fig. 7.20. The weakening of the tension of the toothed belt
|
Allen wrench to turn the 8 mm toothed belt tensioner pulley clockwise to a torque of 15 Nm, remove the locking pin diameter of 2 mm (see. Fig. 7.20), and release the key.
| Fig. 7.19. Location bolts toothed belt and radiator fan bracket 1 - a bolt, 45 Nm; 2 - bolt 10 Nm; 3 - bolt 20 Nm; 4 - bolt 10 Nm
|
Install the cooling fan bracket and fasten the bolts (see. Fig. 7.19). Install poly V-belt. Fill in cooling liquid in cooling system. Start the engine and check the cooling system for leaks.
|