printable version
Check thermostat
| Fig. 2.215. Removing the thermostat: 1 - bypass hose; 2 - lower hose; 3 - a thermostat assembly; 4 bolts thermostat
|
Tie the string so that it was fixed for the working parts of the thermostat. Completely submerge the thermostat in a container of water. Preheat shaking (Fig. 2.215).
Valve opening temperature - the temperature at which the valve opens and falls with the thread (Fig. 2.216). Continue to heat. Check the lifting height when fully opened. After verification of the lift at full opening, reduce the temperature of the water and check the temperature of closing the valve.
Standard values
|