add to favorites contacts sitemap
REPAIR MAINTENANCE OPERATION OF MOTOR VEHICLES
Volkswagen Passat B6 (from the year 2004)

general info. full specifications. diagnostics. hints. tips. tricks
Volkswagen Passat B6
Home
 
Volkswagen
Passat B6
Operation and maintenance of car
Engine
Overview
Mechanical (engine capacity of 1.6 liters)
Lubrication system
Cooling system
Fuel Injection System
The mechanical part (petrol engines of 2.0 liters)
Lubrication system
System ohlazhdeiya
Fuel system
Injection system
General information on the injection system
Removing and installing intake manifold
Removal and installation of atomizers
Checking switching intake manifold
System of release of gases otrabotavschih
Ignition system
The mechanical part (diesel engines of 2.0 liters)
Lubrication system
Cooling system
Fuel system
Turbocharging turbo running on exhaust
The direct injection diesel
Exhaust
Tables
Transmission
Chassis
Steering Gear
Brakes
Onboard electric
Body
diagrams
 


Hit Counter by Digits


print page printable version

Checking switching intake manifold



Carry out the checks only if there is insufficient torque, ie, if there is a lack of flexibility or a lack of traction.
Check valve cycle through the intake manifold using a tester A mode ?�Gefuehrte Fehlersuche / Guided Fault Finding".
If the switching valve intake manifold is undamaged, check the following

Checking procedure
Remove the cover of the vacuum actuator.
Start the engine and let it run at idle. Vacuum unit involved.
The assistant should sharply depress the accelerator pedal. Make sure the vacuum actuated switching intake manifold it should switch.
If the switch does not operate. as described above, check the tightness of the vacuum system, including vacuum reservoir to the intake manifold.
Check the ease of movement of the switching mechanism. To do this, pull the drive rod by hand.
Check the connection of the vacuum pipes.
Check the vacuum hoses for porosity.
Disconnect the vacuum hose to the vacuum actuator switch from the intake manifold switching valve intake manifold 1.

Connect hand vacuum pump to the vacuum actuator switching intake manifold
Fig. 2.236. Connect hand vacuum pump to the vacuum actuator switching intake manifold


Connect a hand vacuum pump to the vacuum actuator switching intake manifold (Fig. 2.236).
Repeatedly press the hand vacuum pump. Link the vacuum actuator should move.
If the drive switching intake manifold does not move
Replace the vacuum actuator drive.