REPAIR MAINTENANCE OPERATION OF MOTOR VEHICLES
Volkswagen Passat B6 (from the year 2004)

general info. full specifications. diagnostics. hints. tips. tricks
Volkswagen Passat B6
Home
 
Volkswagen
Passat B6
Operation and maintenance of car
Engine
Overview
Mechanical (engine capacity of 1.6 liters)
Lubrication system
Cooling system
Fuel Injection System
The mechanical part (petrol engines of 2.0 liters)
Lubrication system
System ohlazhdeiya
Fuel system
Removal of the fuel from the fuel tank when filling the fuel tank more than 3/4
Pumping of fuel from the fuel tank is less than 3/4
Check the functioning and power
Checking fuel pressure
Check of residual pressure
Performance Verification
Electronic control of engine power (electronic throttle actuator)
Removal and installation of the accelerator pedal assembly
Absorber
Check pumping fuel tank
Injection system
System of release of gases otrabotavschih
Ignition system
The mechanical part (diesel engines of 2.0 liters)
Lubrication system
Cooling system
Fuel system
Turbocharging turbo running on exhaust
The direct injection diesel
Exhaust
Tables
Transmission
Chassis
Steering Gear
Brakes
Onboard electric
Body
diagrams
 


Hit Counter by Digits


print page printable version

Performance Verification



Test conditions
Minimum voltage on the battery should be 11.5 V.
SD34 fuse in the fuse block on the right in the front panel to be functional.
The control unit of the fuel pump must be in good condition.

Engines BLR, BLX, BLY
Low fuel pressure sensor must be defective.

Checking procedure
Remove the rear seat.

The cover unit and the fuel supply control module
Fig. 2.204. The cover unit and the fuel supply control module


1 Remove the cover from the control unit of the fuel pump 2 to the fuel supply unit (Fig. 2.204).

Plug and fuel
Fig. 2.205. Plug and fuel


Disconnect the 5-pin connector from the flange (Fig. 2.205).

Pin connector of the fuel pump
Fig. 2.209. Pin connector of the fuel pump


Connect the remote control through the auxiliary wire to pin 1 (+) of the fuel pump and to pin 1 (+) - 10-pin connector (Fig. 2.209).
Connect the terminals 6 (-) - 10-pin connector and 5 (-) of the fuel pump of the auxiliary cable kit auxiliary measuring means.
Remove the filler cap of the fuel tank.
Disconnect the fuel feed line 2 and beneath the escaping fuel rags.

NOTE
To disconnect the fuel line, click on the lock ring.


Connect a manometer
Fig. 2.210. Connect a manometer


Connect the manometer with double nipple and a set of adapters to the fuel feed (Fig. 2.210).
Fit the adapter hose adapter gauge and keep it pointed in a measuring vessel.

ATTENTION
When you open the faucet there is a danger of fuel spray; to avoid injuries and skin contact, wear protective goggles and gloves. Substitute under an open connection capacity gauge.

Open the valve pressure gauge. The lever indicates direction of flow A.
Enable remote control. It should slowly close the tap until the pressure gauge will show 4 bar overpressure. After this, the valve position does not change.
Empty the measuring container.
The performance of the fuel pump depends on the battery voltage. Therefore connect the multimeter wires from a set of auxiliary measurement means to the battery.
Turn on the remote control for 30 C at the same time, measure the battery voltage.

Diagram of nominal values of fuel
Fig. 2.211. Diagram of nominal values of fuel


Compare the amount of fuel with a nominal value (Fig. 2.211).
Example:
During check battery voltage is measured, ravnoe12,5 V. As the voltage on pump 2 at lower battery voltage, the minimum amount of feed is about 580 cm 3/30 sec.
*) - Minimum performance cm 3/30
**) - Voltage at fuel pump with engine stopped and the pump is running (about 2 less than battery voltage).
If the setpoint pressure is not achieved, check the fuel line for kinks and blockages.
If no fault is found, remove the fuel delivery unit and check the strainer for contamination.
If also here no errors are found, replace the fuel filter flange
Repeat the test.
If nominal value is not reached again, faulty fuel pump, replace the fuel delivery module.
Nominal capacity of fuel is reached, however, a fault in the power supply system has not yet ruled out (eg. A temporary failure of the power supply system)
Check the current consumption of the fuel pump.

Check power
Checking procedure
Remove the rear seat.
1 Remove the cover from the control unit of the fuel pump 2 to the fuel supply unit (Fig. 2.204).

Installation of heat-measuring mite
Fig. 2.212. Installation of heat-measuring mite


Connect multimeter using current clamp A to the wire in the terminal 1 the 5-pin plug connector (Fig. 2.212).
Start the engine and leave it idling.
Measure the power consumption of the fuel pump. The nominal value of max. 9 A.

NOTE
If an error occurs in the power supply only from time to time, the check can also be carried out during the test drive, but this requires a second specialist.

If power is exceeded, then
faulty fuel pump, replace the fuel delivery module.




« previos page
Check of residual pressure
next page »