add to favorites contacts sitemap
REPAIR MAINTENANCE OPERATION OF MOTOR VEHICLES
Mazda 3 (2003 release)

general info. full specifications. diagnostics. hints. tips. tricks
Mazda 3
Home
 
Mazda
3
Operation and maintenance of car
Engine
Transmission
Chassis
Steering Gear
Brakes
Onboard electric
Overview
Power supply system
Accumulator battery
Generator
Checking on the vehicle
Check current at the generator
Removing and installing the generator
Removal and installation of high-voltage wires
Starter
Lighting system
Screen wipers and washer
Immobiliser
Electrical Inspections
Tables
Body
 


Hit Counter by Digits


print page printable version

Checking on the vehicle



Check the voltage at the terminals of the generator.
Make sure the battery is fully charged.
Make sure that the belt tension and deflection generator at the standard value.
Turn off all electrical consumers.
Turn the ignition switch to the <START> and make sure that the generator rotates uniformly and does not make noise during engine operation.

Connector Generator
Fig. 7.8. Connector Generator


Measure the voltage between the terminals of the generator (see. Fig. 7.8) at idle (at 20 ?� C) Table 7.2.




« previos page
Generator
next page »
Check current at the generator

Copyright © 2010 AutoManuals.biz. Trademarks belong to their respective owners. All rights reserved.