Removal, check and installation of the gauge of neutral and reverse
Location sensor neutral and reverse
| - After installing the sensor, make sure there are no leaks in the transmission oil.
- To check the sensor connector, disconnect it and check the wiring for continuity between the contacts of the sensor.
 | The numbering of the contacts (1-2-3) goes from left to right when facing up the connector lock. |
- Between terminals 1 and 2 must be conductivity at reverse gear, and between terminals 2 and 3 - Manual transmission in neutral. The remaining provisions of the conductivity should not be.
|
|
|
|