printable version
Removal and installation of the cooling system fittings
Withdrawal Drain the coolant. Remove the coolant hoses from unions. Disconnect the connector from the coolant temperature sensor G62. Remove the mounting bolts fitting the cooling system.
| Fig. 2.246. Installing the connector fitting cylinders in the cooling system
|
Slide cylinder connectors in the arrow direction in the nozzle of the cooling system 1 (Fig. 2.246).
Setting Install in reverse order, with the following should be considered. Replace packings 2 and O-rings. Tighten mounting bolts fitting the cooling system 1 to 8 N ?� m. Fill in cooling liquid.
|