add to favorites contacts sitemap
REPAIR MAINTENANCE OPERATION OF MOTOR VEHICLES
Chevrolet Lanos (since 2004 of release), Daewoo Lanos (since 1997 of release)

general info. full specifications. diagnostics. hints. tips. tricks
Chevrolet Lanos
Home
 
Chevrolet
Lanos
Device Car
Operating Guidelines
Faults in the way
Maintenance
Engine
Design Features
Compression check in cylinders
Removal and installation of mudguards of the engine
Mount Replacement power unit
Installation of the piston of the first cylinder to TDC of the compression stroke
Removal, installation and Troubleshooting flywheel
Replacement parts Seal Engine
Cylinder Head
Removing and installing engine
Engine repair
Lubrication system
Cooling system
Exhaust
The power supply system of the engine
The system EVAP
Device features
Removal, installation and check of the canister purge valve
Removal and installation of the adsorber
Exhaust gas recirculation
Transmission
Chassis
A steering
The brake system
Electrical
Body
Wheels and tires
Purchase of spare parts
A trip to the STO
Winter car operation
Preparation for technical inspection
Tips novice mechanic
Applications
Diagrams
 


Hit Counter by Digits


print page printable version

Removal, installation and check of the canister purge valve



You will need a flat-blade screwdriver.
1. Disconnect a wire from the plug "minus" of the storage battery.
2. Press the plastic latch Disconnect the harness from the canister purge valve.
3. Disconnect the inlet and outlet hoses from the valve fittings.
4. Press the screwdriver spring clamp valve ...
5. ... and remove the valve from the bracket.

NOTE
It looks like the car removed from the canister purge solenoid valve. Note his marking to the replacement valve to set the same.

6. To check the valve, attach to a discharge valve fitting medical syringe (it is used as a pump, and the vacuum supply hose to the valve, you can use as an adapter for connection of a syringe). Push the plunger of the syringe - in the valve pressure to be created (you can feel the aspiration of the syringe plunger back to its original position).
7. Then connect the valve to the conclusions of a DC source voltage of 12 V - the valve should open and the pressure should disappear (syringe plunger will move without resistance all the way). Otherwise, replace the valve.
8. Install the canister purge valve in the reverse order of removal.




« previos page
Device features
next page »
Removal and installation of the adsorber