printable version
Checking the charging circuit
PERFORMANCE ORDER | 1. Turn on the ignition. | 2. After switching on the ignition with the engine running, the test lamp should illuminate charging. | | 3. Disconnect the connector from the resistor pre-excitation of the generator. Connect an ohmmeter to terminals 1 and 3 of the connector from the component. Positive dipstick () ohmmeter connected to the terminal 3 and the negative test lead (-) - to terminal 1. | A warning If an ohmmeter is not connected properly, it will not show the resistance value
|
| Result
PERFORMANCE ORDER | 1. If there is a conductivity shows ohmmeter, means the electrical circuit in order. If conductivity is absent, then the electrical connection is faulty. | 2. If the conductivity is not only in step 3, check and restore electrical circuit control lamp. If conductivity is absent only in step 2, check the resistor pre-excitation of the generator. | A warning If the conductivity is not only one of the steps 2 and 3, then the system is working properly, however, for more reliable operation of the system is necessary to inspect the electrical circuit.
|
|
|