add to favorites contacts sitemap
REPAIR MAINTENANCE OPERATION OF MOTOR VEHICLES
Kia Magentis / Optima (2000 release)

general info. full specifications. diagnostics. hints. tips. tricks
Kia Magentis
Home
 
Kia
Magentis
Engines
Lubrication System
Cooling system
The control and toxicity
Fuel system
Ignition system
Coupling
Transmission
Power shafts, axles
Suspension
Steering
Brakes
Body
The air conditioning system
Electrical equipment
Technical data
Charging System
Checking the voltage drop across the wire connecting the battery to the generator (engine V6)
Check of the current generated by the generator
Check voltage release
Checking the voltage drop across the wire connecting the battery to the generator (the engine 2,0)
Check of the current generated by the generator (engine 2,0)
Checking the generated voltage (2.0 liter engine)
Generator
Accumulator battery
Inspection of battery
Starting system
Removing and installing starter
Installing Transceiver
Removal and installation of remote control
Removal and installation of the audio unit
Multifunction switch
Circuit breakers
Device combination
Switch position of the parking brake
Rear Defrost
Wipers and windshield washer
Airbags (SRS)
Warning Labels
Airbag and a spiral wire
The front passenger airbag
Troubleshooting charging system
Troubleshooting engine starting system
Electrical diagrams
 


Hit Counter by Digits


print page printable version

Check of the current generated by the generator



This check is to determine whether the generator generates a current which is equivalent to the nominal capacity.

Preparing for inspection

PERFORMANCE ORDER

1. Before the test, check the following items:

  • the state established in the car battery;
  • alternator drive belt tension.

The battery, which is used to check the current produced by the generator must be partially discharged. When fully charged the battery test can not be performed due to insufficient load generator.

2. Turn off the ignition.
3. Disconnect the negative battery terminal.
4. Disconnect the terminals "B" of the generator.
5. Connect the DC ammeter to measure the limit of 0-100 A in series between the terminal "B" and disconnected from the alternator wire. Make sure that the negative probe of the ammeter connected to the generator disconnected from the wire.

Connect the wires and the ammeter probes are very reliable, since the chain will flow a large current.

6. Connect a voltmeter (0-20) between terminal "B" of the generator and "weight". Make sure that the positive probe of the voltmeter connected to the terminal "B" of the generator.
7. Connect the tachometer and wire to the negative terminal of the battery.

8. Leave the hood open.

Check

PERFORMANCE ORDER

1. Check that the scale is clearly visible voltmeter to determine the voltage. If the voltmeter shows voltage of 0V, then do not complete an electrical circuit connecting the terminal "B" of the generator and the battery negative terminal, burned fuse or bad connection with "weight".
2. Start the engine and turn on the lights.
3. Turn on the main beam headlights and the heater fan at maximum air supply. Briefly increase the speed of the crankshaft of the engine to 2500 min-1 and the value read on the devices, while an ammeter shows the current produced by the generator.

After engine start battery charging current decreases very rapidly, so this test should be performed very quickly.

Result of checking

PERFORMANCE ORDER

1. The ammeter reading should be greater than the limit value. If the current value is less than the limit value, and a wire connecting the output of the generator, in order, remove the generator from the car and check it out.

The current limit for generator A 95: 63.0 A

The current limit specified on the label attached to the body of the generator.

Electricity produced by the generator depends on the temperature and the load. Therefore, to limit discharge current battery upon enabling lights on the car with engine inoperative.

The limiting value of current generated by the generator can not be obtained if the temperature of the generator or the ambient air is too high.

2. After completion of the test limit current produced by the generator, turn the engine to idle and turn the ignition off.
3. Disconnect the negative battery terminal.
4. Remove the tachometer, voltmeter and ammeter.
5. Connect a wire to the terminal "B" of the generator.
6. Connect the cable to the negative terminal of the battery.





« previos page
Checking the voltage drop across the wire connecting the battery to the generator (engine V6)
next page »
Check voltage release