add to favorites contacts sitemap
REPAIR MAINTENANCE OPERATION OF MOTOR VEHICLES
Mazda 3 (2003 release)

general info. full specifications. diagnostics. hints. tips. tricks
Mazda 3
Home
 
Mazda
3
Operation and maintenance of car
Engine
General description new engines models L8, LF, L3
The mechanical part of engines
Appendix 1
Annex 2
Appendix 3
Control system
The principle of operation and the appointment of some components of the control system
Fault codes
Fault codes
Synchronization camshaft
Heater oxygen concentration sensor
The pressure sensor in the intake manifold
The pressure sensor in the intake manifold
Sensor IAT (Intake Air Temperature)
Throttle Position Sensor
Fuel system
Monitoring the misfire
Knock sensor
EGR valve
Neutralization system
Bleed solenoid valve
The control system cooling fans
Neutral Switch
The solenoid valve intake system with variable characteristics (VAD)
The PCM
The control system of air mixing
Barometric Pressure Sensor
Generator
Engine Z6 - mechanical part
Lubrication system
Cooling system
Intake system
Fuel system
Exhaust and Emission
Ignition system
Control system
Tables
Transmission
Chassis
Steering Gear
Brakes
Onboard electric
Body
 


Hit Counter by Digits


print page printable version

Heater oxygen concentration sensor



The low level of the input circuit of the heater front oxygen concentration sensor (P0031)
The PCM controls the heater control signal forward gauge of concentration of oxygen in the heating unit 4A output PCM. If the PCM deactivates the heater front oxygen concentration sensor heater, the heater circuit and the oxygen concentration sensor front heated has a low voltage, the PCM block decides that heater circuit is faulty.

The high level of the input circuit of the heater front oxygen concentration sensor (P0032)
The PCM controls the heater control signal forward gauge of concentration of oxygen in the heating unit 4A output PCM. If the block PCM front sensor includes a heater heated the oxygen concentration, and the front sensor circuit heater heated oxygen concentration is high voltage, the PCM block decides that heater circuit is faulty.

The low level of the input circuit of the heater rear oxygen concentration sensor (P0037)
The PCM controls the heater control signal to the rear oxygen concentration sensor heated at terminal block 4D PCM. If the PCM turns off the heater rear oxygen concentration sensor heater, the heater circuit and rear oxygen concentration sensor heating has a low voltage, then the PCM determines that the heater circuit is faulty.

The high level of the input circuit of the heater rear oxygen concentration sensor (P0038)
The PCM controls the heater control signal to the rear oxygen concentration sensor heated at terminal block 4D PCM. If the PCM turns the heater rear oxygen concentration sensor heater, the heater circuit and rear oxygen concentration sensor heating has a high voltage, then the PCM determines that the heater circuit is faulty.