printable version
Draining ATF and filling
Stop the engine.
Remove the drain plug for the control of level ATF in the oil sump (Fig. 3.70).
Remove the overflow tube 1 through the inspection hole (Fig. 3.72). Drain ATF. Install the overflow pipe. Tighten the plug by hand. Pour through the filler tube 3 liter ATF. Start the engine and switch the selector in all positions, holding it in each position about 10 seconds. Check and bring oil level ATF.
|