Power steering pump
Withdrawal Dismantling Check | - Measure the length of the spring of the check valve in a free state. The length of the spring in a free condition of 36.5 mm.
- Make sure that the control valve is not bent.
- Check the shaft for wear and damage.
- Check the drive belt for wear and loss of properties.
- Check the grooves of the rotor and blades for wear.
- Check the contact surface of the stator ring and the blades for wear.
- Check the blade for damage.
- Check for wear side plate and the contact surface of the shaft and the pump cover.
|
|
Assembly | - Install the spring check valve and a connector valve in the pump housing.
| - The special tool 09222-32100 install oil seal in the pump housing.
|
| - Gently insert the shaft assembly and install the spacer and the retaining ring.
|
| - Install pump pulley with the woodruff key.
|
- Install the spring and the inner sealing ring.
| - Install the outer O-ring in the side plate and set the front side plate.
|
| - Insert the pins into the recesses of the front housing, then install the cam ring, paying attention to the direction of installation.
|
- Set the rotor so that the marks on the rotor located on the side opposite the front of the housing.
| - Set the blade rounded out parts.
|
- Place the gasket and pump cover.
- Install the suction pipe and the O-ring.
|
|
Setting | | - Place the pump on the bracket, put the belt on the pulleys and tighten the belt tension adjustment bolt. Torque: 3.5-10 N ??? m.
|
- Install the suction filter.
- Connect to the pump pressure hose.
| Install the pressure hose so that it is not twisted and does not come into contact with any other parts. |
- Pour the liquid. Recommended fluid: PSF-3.
- Bleed the hydraulic power steering.
- Check the pressure created by the pump.
|
|
|
|