printable version
Checking the return anchor of the traction relay
Disconnect the field coil wire from terminal "M" pulling the relay.
| Fig. 7.60. The scheme of check return anchor of the traction relay
|
Connect the wires from the terminals 12 V battery to a conclusion "M" and the starter housing (Fig. 7.60).
ATTENTION This test must be carried out quickly, no more than 10 seconds, to prevent the coil from burning starter. |
Pull hand pinion gear and release. If the pinion gear is immediately returned to its original position, then the traction relay correctly. If not, replace magnetic switch.
|