add to favorites contacts sitemap
REPAIR MAINTENANCE OPERATION OF MOTOR VEHICLES
Hyundai Sonata (2001 release)

general info. full specifications. diagnostics. hints. tips. tricks
Hyundai Sonata
Home
 
Hyundai
Sonata
General Information
Engine
Transmission
Steering
Chassis
Brakes
Body
Additional security
Systems of heating, ventilation and air conditioning, air-
Overview
Technical data and features
Check fault
The air conditioning system
Handling Refrigerant
Drain the refrigerant from the air conditioning system
Replacing parts in the air conditioning system
Removal of odors from the air conditioning system
Installation of fasteners
Install manifold gauges
Pumping air-conditioning system
Attaching the valve to the refrigerant container
Filling the air conditioning system
The electronic leak detector
Checking the oil level
Check hoses and tubes
Check the performance of the air conditioning system
Removing and installing air conditioner compressor
Repair air conditioning compressor
Testing the air-conditioning system installed in the car
Sensors air conditioning system
Electrical
Diagrams
 


Hit Counter by Digits


print page printable version

Pumping air-conditioning system



WARNINGS
When the air conditioning system is open, i.e., connected to the atmosphere such as during the installation or repair by a vacuum pump system of the air must be pumped.
After installation of the air conditioning system elements must be pumped for 15 min. Node, which opened for repair and maintenance, it is necessary to pump over 30 minutes.

Pumping spend on a car with a dead engine.
Connect the measuring gauge manifold to the port of the compressor.
Close the valves of high and low pressure.
Make sure that the refrigerant drained from the air conditioning system.
Attach the center hose of the gauge manifold to the inlet of the vacuum pump.
Let the vacuum pump and open the valves of high and low pressure.
After 10 minutes, check that the vacuum is equal to 94.39 kPa. If it is impossible to achieve the desired dilution, then the air conditioning system has a leak which must be eliminated in the following order:
- Close both valves of the gauge manifold and stop the vacuum pump;
- Fill the air conditioning system 0.4 kg of refrigerant;
- Leak detector, check the tightness of the air conditioning system and eliminate any leak detected;
- Drain the refrigerant from the air conditioning system, and then follow the pumping system. If leaks are found, continue to pump out system.
Let the vacuum pump.
Open both valves to obtain a vacuum 94.39 kPa.
Once the low pressure gauge shows a vacuum which is close to 94.39 kPa continue pumping an additional 15 min.
After evacuation for 15 minutes, close the valve and stop the vacuum pump. Disconnect the hose from the vacuum pump. The system is now ready for refueling.




« previos page
Install manifold gauges
next page »
Attaching the valve to the refrigerant container

Copyright © 2010 AutoManuals.biz. Trademarks belong to their respective owners. All rights reserved.