printable version
Checking the oil control valve (OCV) (L3)
Disconnect the negative battery cable. Disconnect the connector of the oil control valve.
Measure the resistance between terminals A and B using an ohmmeter (Fig. 2.103). If the result is different from the specified, replace the control oil valve.
| Fig. 2.117. Conclusions connector control of the oil valve (OCV)
|
The standard description of the indications of an ohmmeter - 6,9-7,9 Ohm.
|