printable version
Removing and installing hydropushers
| Fig. 116. Valve hydropushers (cross-sectional): 1 - the push pin (rod); 2 - a lock ring; 3, 5 - pressure springs; 4 - ball; 6 - the directing plug; 7 - a guide for the ball
|
Removing hydropushers valves (Fig. 116) should be carried out in the following order: - Remove the camshaft (Sect. 2.12.6); - With the help of suction cups to remove the pusher or pushers from their wells in order and immediately mark their identity. When installing the lower jacks in their wells in the case of repeated use. Install the camshaft (Sect. 2.12.6) and all other parts in the reverse order of removal. In Fig. 116 is a sectional view of the valve with hydropushers and compensator, which gives an idea of the location details.
|