add to favorites contacts sitemap
REPAIR MAINTENANCE OPERATION OF MOTOR VEHICLES
Volkswagen Transporter, Caravelle (1990 release)

general info. full specifications. diagnostics. hints. tips. tricks
Volkswagen Transporter / Caravelle
Home
 
Volkswagen
Transporter / Caravelle
Instructions
Engine
Coupling
Transmission
Suspension
A steering
Brakes
Wheels and tires
Body
Electrical
Electrical system
Installation of additional electroaccessories
Troubleshooting in electrical equipment
Relay
Wiper motor
System of indexes of turns
Stop signal
Sound signal
Heated rear window
Replacing fuses
Accumulator battery
Removing and installing the battery
Checking the battery
Charging the battery
Storage Battery
Samozaryad battery
Troubleshooting Battery
Warning lights
LEDs
Voltage regulator
Switchgears
Roller speedometer
Generator
Starter
The lighting system and alarm
Wiring
 


Hit Counter by Digits


print page printable version

Samozaryad battery



Depending on the configuration of the machine to the natural self-discharge of the battery is also added to the current consumption of the various control devices during storage. Therefore, every 6 months, the battery must be recharged. If there is a suspicion of surface currents, check the on-board network as follows:

PERFORMANCE ORDER
1. To test the use-charged battery.
2. Turn off the ignition.
3. Fit the ammeter (measuring range 0-5 mA to 5 A), the largest measuring range. Disconnect the ground cable from the battery. Connect an ammeter to the negative pole of the battery and the cable weight.

A warning

Verification can be made and control lamp. If the lamp is connected to the negative pole of the battery and the negative cable, still does not light, you need to connect an ammeter.


4. Turn off all electrical consumers: the available hours (regular customer) disconnect, close the door.
5. Switch ammeter milliampermetrovuyu in the region as long until the current (1-3 mA allowed).
6. When removing the fuses in series, to break off the circuit. If any indication of an open circuit drops to zero, the search for the source of the fault here. Faults can be: corroded and dirty contacts, pureed wire, internal circuit in the unit.
7. If a fault in the protected circuit will not be found, it is necessary to disconnect the wiring of the unprotected circuits. These are: the generator, starter, ignition system.
8. If you disconnect the unit unprotected arrow falls to 0, check or replace the unit. When leakage current in the starter or ignition system, check the wiring on the ignition (see. Subsection 10.20.7).
9. Connect the ground cable (-) to the battery.

A warning

Connect the battery only when the ignition is switched off, otherwise it may be damaged control unit injection system.


10. Set the time on the clock.
11. Enter the anti-theft radio code.