printable version
Checking the engine by means of the vacuum gauge
Fundamentals and arrows gauge fluctuations in the diagnosis of malfunctions of the engine Using the gauge, you can get information about the state of the engine and determine that the broken cylinder head gasket, damaged power supply system, damaged ring properly regulated power system, damaged valves, etc. Unfortunately, the gauge readings can be correctly interpreted, however, these measurements must be used in conjunction with other methods of checking the engine. For the correct definition is important as the absolute value of the vacuum reading, and their rate of change. | - Connect the vacuum gauge to the intake manifold. Start and warm up the engine to normal operating temperature.
- Consider the testimony of the gauge. If the engine is in normal condition, the gauge readings should be 430-560 mm. Hg. Art., and the gauge needle should be in place.
- Low constant gauge readings indicate that the damaged gasket between the intake manifold and the throttle body, vacuum hose is damaged, improperly installed ignition timing or incorrect timing.
- If the gauge readings below the norm of 80 - 200 mm. Hg. Art. and fluctuate, it may be damaged gasket intake pipe near the inlet or faulty injector.
- If the readings are constantly falling for 50 - 100 mm Hg. Art. relatively stable values, it may be damaged valves. In this case, you need to measure the engine compression.
- If the readings are falling, but not regularly, then maybe it jammed valve or a malfunction occurs in the ignition.
- If indications quickly fluctuate with the amplitude of about 100 mm. Hg. Art., at constant idle, and from the exhaust smoke, possibly damaged valve guides.
- If the readings fluctuate rapidly with increasing idle speed, it may be damaged intake manifold gasket or cylinder head gasket, weakened valve springs, valves or burned there is a failure in the ignition.
- Small fluctuations around 25 mm Hg. Art. usually associated with failures in the ignition system.
- If the readings vary greatly, it may be damaged cylinder head gasket or cylinder.
- If the needle is slowly moving in a wide range of values, it is possible that the controlled system is clogged crankcase ventilation, intake manifold gasket is damaged or the seal between the throttle body and the pipe.
- Check how quickly restored after a sharp gauge readings and fully open throttle and return it to its original position. If the engine is in a normal state, indications fall almost to zero, and then increases by about 130 mm. Hg. Art. above the norm and again decrease to former values at constant idle. If the readings are restored slowly and pass through a maximum after closing the throttle, then maybe damaged piston rings. If there is a long delay, it is possible that the exhaust system is clogged.
|
|
|