add to favorites contacts sitemap
REPAIR MAINTENANCE OPERATION OF MOTOR VEHICLES
Hyundai Elantra (from 2000 to 2004, the year of issue)

general info. full specifications. diagnostics. hints. tips. tricks
Hyundai Elantra
Home
 
Hyundai
Elantra
Gasoline engines 1.6, 1.8 and 2.0 liters
The diesel engine of 2.0 liters
Greasing system
Cooling
Fuel system
Control systems and emission control
Ignition system
The system of preliminary heating of the diesel engine
Coupling
Manual transmission
Automatic Transmission
Drive shafts, front and rear axles
Suspension
Steering
Brakes
Body
The air conditioning system
Electrical equipment
Technical data
Charging System
Generator
Check the voltage drop across the wire that connects the battery to the alternator
Check of the current generated by the generator
Check voltage release
Generator petrol engines
Generator Diesel Engine
Accumulator battery
Starting system
Starter gasoline engines
Starter Diesel Engine
Circuit breakers
Fuse
Multifunction switch
Sound signal
Device combination
Switch position of the parking brake
Wipers and windshield washer
Rear window wiper
Headlights and front blinkers
Front fog lamps and turn signal
The rear combination lamp
High level brake light
The lantern light plate
Ceiling light (with sunroof)
Ceiling light (without sunroof)
Interior light
Check of the relay of headlights
Radio
Rear Defrost
Airbags (SRS)
Seat belts
Troubleshooting
Basic data for the adjustment and control
Electrical diagrams
 


Hit Counter by Digits


print page printable version

Check of the current generated by the generator



This check is to determine whether the generator generates a current which is equivalent to the nominal capacity.

Preparing for inspection

PERFORMANCE ORDER

  1. Before the test, check the following items:
    1) The state established in the car battery;
    2) belt tension generator.

The battery, which is used to check the current produced by the generator must be partially discharged. When fully charged the battery test can not be performed due to insufficient load generator.

  1. Switch off the ignition.
  2. Disconnect the negative battery terminal.
  3. Disconnect the wire from the plug ?�B?� generator.

Connect the wires and the ammeter probes are very reliable, since the chain will flow a large current.

  1. Connect the DC ammeter to measure the limit of 0-100 A in series between the plug ?�B?� and disconnected from the alternator wire. Make sure that the negative probe of the ammeter connected to the generator disconnected from the wire.
  2. Connect a voltmeter (0-20) between the plug ?�B?� of the generator and "weight". Make sure that the positive probe of the voltmeter connected to the plug ?�B?� generator.
  3. Connect the tachometer wire to the negative terminal of the battery.
  4. Leave the hood open.

Check


PERFORMANCE ORDER

  1. Check that the scale is clearly visible voltmeter to determine the voltage. If the voltmeter shows voltage of 0V, then do not complete an electrical circuit connecting the terminal ?�B?� of the generator and the battery negative terminal, burned fuse or bad connection with "weight".
  2. Start the engine and turn on the lights.
  3. Turn on the main beam headlights and the heater fan at maximum air supply. Briefly increase the speed of the crankshaft of the engine to 2500 min-1 and the value read on the devices, while an ammeter shows the current produced by the generator.

After engine start battery charging current decreases very rapidly, so this test should be performed very quickly.

Result of checking

PERFORMANCE ORDER

  1. The ammeter reading should exceed the limit value. If the current value is less than the limit value, and a wire connecting the output of the generator, in order, remove the generator from the car and check it out. The current limit: 63.0 A generator 90 A.
  1. The current limit specified on the label attached to the body of the generator.
  2. Electricity produced by the generator depends on the temperature and the load. Therefore, to limit discharge current battery upon enabling lights on the car with engine inoperative.
    The limiting value of current generated by the generator can not be obtained if the temperature of the generator or the ambient air is too high.
  1. After completion of the test limit current produced by the generator, turn the engine to idle and turn the ignition off.
  2. Disconnect the negative battery terminal.
  3. Remove the tachometer, voltmeter and ammeter.
  4. Attach the wire to the terminal ?�B?� generator.
  5. Attach the wire to the negative terminal of the battery.




« previos page
Check the voltage drop across the wire that connects the battery to the alternator
next page »
Check voltage release