Measure the diameter of the valve stem
Measure micrometer core diameter of each valve in the directions X and Y in the three points (A, B, and C) as shown below 2.140. If the diameter is not correct, replace the valve. Standard diameter: - Intake: 5,470-5,485 mm; - Issue: 5,465-5,480 mm. Maximum diameter: - Inlet: 5,440 mm; - Issue: 5,435 mm.
|