1. Close the valve pressure gauge. |
2. Includes remote control at short intervals until the pressure rises to 3 bar. If the pressure exceeds 3 bar, slightly open valve until it falls to 3 bars. |
A warning There exists a danger of fuel spray when opening the tap. Place a container.
|
3. If after a minute the excess pressure of 3 bar is not created, the leaking fuel connections or non-return valve. |
4. Check the pressure drop. After 10 minutes, the pressure should not fall below 2 bar. Otherwise, check the tightness of the fuel connection. |
5. If no fault is found, replace the fuel pump with the check valve. |
6. Disconnect the remote control. |
7. Screw the fuel rail sensor. |
8. Attach the carpet with adhesive tape. |