add to favorites contacts sitemap
REPAIR MAINTENANCE OPERATION OF MOTOR VEHICLES
Mercedes-Benz M-Class (W163, 1997 issue)

general info. full specifications. diagnostics. hints. tips. tricks
Mercedes-Benz W163
Home
 
Mercedes-Benz
W163
Introduction
Controls and receptions of safe operation
Current care and maintenance
Engine
System of cooling, heating and air conditioner
The power supply system and exhaust
Systems of an electric motor
Ignition and engine control
System of preheat of the diesel engine
Diagnostics of systems of electronic control and diagnostic equipment
Charge and start systems
general information
Battery - general information, tips for maintenance
Charge system - the general information and safety measures
Checking the charge
Removing and installing the generator
Removal and installation of the drive pulley of the generator
Removing and installing voltage regulator
The system start the engine - the general information and precautions
Removing and installing starter
Manual box of a gear change
The transmission automatically processed
Transmission Line
Brakes and auxiliary systems
Suspension and steering
Body
Onboard electric
 


Hit Counter by Digits


print page printable version

Charge system - the general information and safety measures



In all these models used alternator. When installing additional electrical equipment, make sure that there is enough generator power to provide electricity to new consumers.

The drive generator is V-belt from the engine crankshaft.

The generator is a three-phase synchronous electric car with electromagnetic excitation. To convert AC to DC generator integrated diode rectifier. Voltage regulation is carried out integrated microelectronic regulator.

When the generator is an electric current flowing through the field winding creates around the poles of the rotor flux. When the rotor is periodically changing its magnetic poles under each tooth of the stator, as a result of passing through the tine magnetic flux is continuously changed in magnitude and voltage. This creates an alternating magnetic flux in the stator winding electromotive force (EMF). The wedge shape of the pole pieces of the rotor is chosen in such a way that allows you to get close to a sinusoidal waveform EMF.

At high rotor speed when the output voltage of the generator exceeds 13.6-14.6 V, the voltage regulator is locked and the current through the field winding does not pass. When the voltage is reduced, the controller is unlocked again, providing freedom of passing a current through the field winding. The higher the rotor speed, the longer the controller is locked and the correspondingly stronger decreases the output voltage of the generator. The process of locking and unlocking the controller comes with a high frequency, so the fluctuations in output remain virtually invisible and the generator voltage can be considered constant, is maintained at 13.6-14.6 V.

The charging system does not require periodic maintenance, but check the status / replacing the drive belt, battery and its wiring must be done on a regular basis in accordance with the Schedule TO (see chap. Power supply system and exhaust).

When the ignition is in the instrument cluster must be briefly activated control lamp of a charge (see chap. Controls and receptions of safe operation). If the lamp is not switched off after a short time after the engine is started or activated in the operation of the latter, you need to make an inspection of the components of the system charge. Disclaimer activate lights when the ignition indicates it fails, the corresponding electrical damage, or infringement of serviceability of functioning of the generator (including the belt is broken).

Safety precautions when servicing the generator

  • Never disconnect the battery or voltage regulator with the engine running;
  • Never short to ground terminal of the generator or the cable fixed to it;
  • Do not confuse the order of the wiring connections of the voltage regulator;
  • Remember that the inclusion is shorted to ground control voltage leads to instant damage it;
  • Never remove the generator when the connected battery;
  • Do not confuse the polarity of the battery;
  • Never use during inspections onboard electric meters voltage / lamp probes connected to the home network (110/220);
  • When checking the state of the diodes do not apply to them a voltage of 12 V and do not use a mega-ohm meters are also having a high output voltage, - the breakdown of the diodes will result in a short circuit. Remember that when checking the insulation of electrical cables using mega-ohmmeter is necessary to disconnect all electrical wiring from the generator whole;
  • When charging the battery without removing it from the car, make sure that it has been disconnected from both wires. Do not confuse the polarity of the battery charger;
  • Before carrying out any electric welding on the vehicle papers do not forget to disconnect the wiring from the generator and battery;
  • Any test of circuits and on-board units produce wiring with the engine off and battery disconnected;
  • Remember that any violation of the polarity of the connections associated with the risk of irreversible failure of the rectifier and the voltage regulator of the generator.