printable version
Removal and installation of gauges of system K / V
Humidity sensor | Details of the air humidity sensor (B31 / 2) |
| - Open the hood.
- Remove the resonator chamber of an air path with Water Collector (see chap. Power supply system and exhaust).
- Having turned 45 ?� in the specified direction of the arrow, remove the humidity sensor (B31 / 2) and disconnect the wiring.
- Installation is in the reverse order - make sure that the wiring of the sensor does not come under the cover of the evaporator.
|
|
Temperature and pressure of the refrigerant Details of the sensor temperature and the refrigerant pressure | - The need for replacement of the sensor occurs in the development of leaks of the refrigerant and at the output to the I / O failure.
| In the course of replacing the sensor, do not allow moisture to the working circuit system! |
- Open the hood.
- Remove the receiver-dryer (1) (see. Section Removal and installation of receiver-dryer) - immediately plug the open ends of the refrigerator lines with suitable plugs.
| The receiver drier is subject to replacement without fail every time the opening of the working circuit of the system K / V - do not forget to take into account the amount of refueling system receiver (see. Specifications)! |
- Release bandage tapes (4) and move toward the cooling hoses tract.
- Disconnect the wiring harness (2) from the temperature sensor and refrigerant pressure (B12 / 2).
- Hold against turning the pressure line (3), unscrew and remove the sensor (B12 / 2).
- Installation is performed in reverse order - do not forget to replace the O-rings before installing them together greasing screwed compressor oil.
- Finally, check the serviceability of the system K / V.
|
|
Evaporator temperature sensor Details of installation of the evaporator temperature sensor (B10 / 6)
|